Skip to content

Energy and water software for hotels

A virtual chief engineer for every hotel.

See where energy and water costs can come down. Cadae’s AI prepares the next steps for your team to review and approve.

For one hotel or a whole portfolio.

Your bills show what you spent. They do not show what to fix.

Bring readings and building knowledge together. See what needs investigation, what deserves investment, and what still needs evidence.

See the work take shape.

Follow one hotel through the evidence, an AI-prepared investigation, and the check on its outcome. People review and approve the work.

Harbour Court

Overall PHI

Poor
Best in class = 0
11 of 12 months published

Energy PHI

Poor
Best in class = 0
11 of 12 months published

Water PHI

Needs attention
Best in class = 0
11 of 12 months published

CO₂

339.5 tCO₂e

Reported separately from the PHI score

Electricity use and best in class · kWhMonthly readings. A difference is a reason to investigate.
Show the data table
Electricity use and best in class · kWh
SeriesMonthValueUnitBasisSource
Recorded useJan 202576,000 kWhkWhMeasuredMeter records / hotel model
Recorded useFeb 202572,000 kWhkWhMeasuredMeter records / hotel model
Recorded useMar 202584,000 kWhkWhMeasuredMeter records / hotel model
Recorded useApr 2025100,000 kWhkWhMeasuredMeter records / hotel model
Best in classJan 202565,000 kWhkWhModelledMeter records / hotel model
Best in classFeb 202564,000 kWhkWhModelledMeter records / hotel model
Best in classMar 202568,000 kWhkWhModelledMeter records / hotel model
Best in classApr 202570,000 kWhkWhModelledMeter records / hotel model

Every hotel. Every financial decision.

See utility spend, capital plans and approvals together. Open a hotel, compare its budget and review the work awaiting a decision.

Open the financial dashboard
CadaeCadaePortfolio · Financial dashboard
HC
2026Year to date

Hotels by status

10

3 Needs review5 On track2 No budget

Utilities · Opex

£1,965,587

Actual / forecast · 8 of 10 hotels

Budget £1,860,628 · 8 of 10 hotels

Capital · Capex

£137,165

Selected projects across the portfolio

3 of 10 hotels

Projects

19

Awaiting approval 10

Every hotel. One status per line.

HotelRoomsBudgetActual / forecastUtilities · OpexCapital · CapexProjects
169£600,628£694,487Needs reviewOn track7 Awaiting approval
78£176,000£186,900Needs reviewOn track2 Awaiting approval
Not available£118,000£120,400On trackNot available1 Awaiting approval
Not available£296,000£302,100On trackNeeds reviewOn track
114£221,000£214,000On trackOn trackOn track
56£160,000£163,800On trackNot availableOn track
105£190,000£187,900On trackOn trackOn track
37£99,000£96,000On trackOn trackNot available
Not availableNot availableNot availableNot availableOn trackNot available
232Not availableNot availableNot availableOn trackNot available

The totals cover the hotel records shown. Budget gaps remain visible. Open a hotel to inspect its monthly budget.

Understand the building behind the bill.

See the building as a connected system. Follow demand to the equipment, review operating patterns and prepare the right next action.

Energy Monitoring

Harbour Court

Building systems14:30 snapshot
Building systems
Air handling

56 kW

Needs review
Observation
The operating schedule is not confirmed. Check operating hours before proposing a change.
Review rule
Review occupied areas, service hours, guest comfort and air quality.
Source
Equipment sub-meter · 14:30

Monitored equipment only. One meter is unavailable.

Select a system to inspect its reading.

Monitored load

268 kW

Reading coverage

6 of 7 equipment readings available

Laundry

Not available

Show all equipment readings
EquipmentReadingStatus
Chillers135 kWActive
Air handling56 kWNeeds review
Pumps62 kWActive
Kitchen3 kWActive
Pool and spa5 kWActive
Extract fans7 kWActive
LaundryNot availableNot available
Monitored load268 kW6 of 7 equipment readings available

Know what is possible. Know what is proven.

Keep the performance cost gap, Project estimates and verified savings separate. Make decisions with figures you can trace.

Performance cost gap

£184,200

Proposed savings

£96,400

Verified savings

£31,250

These are three different measures. They are never added together.

Understand the numbers

Built around your hotel.

30 years of hotel engineering, a model of your property, and a practical plan for the next decision.

How Cadae works

Energy

Investigate heating, cooling and equipment use. Plan the changes worth making.

Explore energy

Water

Understand demand. Investigate unexplained use. Plan changes that fit the hotel.

Explore Cadae for Water

A clearer next step for every hotel.

Bring your energy and water questions. Explore the findings, proposed work and evidence in a Cadae demo.